Industry dynamics

Contact us

Zibo Haibao Vacuum Equipment Co., Ltd.

Tel:0533-4680608

Fax:0533-4680822

Mob: 13705334335

E-mail:zbhaibao@163.com

Add:Yan Bei Road, Boshan District, Zibo, Shandong


Industry dynamics

Position: Home > Industry dynamics

Measures to solve the trip of SK water ring vacuum pump

Add time:2018-09-24 21:46 Hits:

When we use the SK water ring vacuum pump, it often trips, which seriously affects the normal use of the pump. So, what are the measures to solve the tripping of the SK water ring vacuum pump?
1. When the SK water ring vacuum pump is running, if the current exceeds the current set by the electric control box, the vacuum pump will trip and trip off. At this time, the upper limit of the high current protection can be adjusted to solve the tripping phenomenon;
2. If the machine is connected to the two-phase power supply and the three-phase power supply is not enabled, the three-phase power supply should be turned on immediately. If there is a trip or tripping after the hour of operation, the current upper limit should be adjusted.
3. When the vacuum pump exhaust port inhales foreign matter or impurities and causes motor load, the vacuum pump should be disassembled and checked for faults inside the pump;
4. If the vacuum pump is deactivated for a long time, the motor load will cause the temporary current to be too high. At this time, the air inlet can be closed, and the pump can be operated to heat the pump body;
The cause of the tripping problem of the SK water ring vacuum pump. When the pump trips or trips, we should find the cause in time so that we can handle and solve the problem well.
Online
Share